Models, specifications, and compatibility
|
Product name (SKU) |
DOM‐ Digital Optical Monitoring |
Nominal wl (nm) |
Fiber mode and connector type |
Fiber Diameter |
Modal Bandwidth |
Distance |
|---|---|---|---|---|---|---|
|
HPE Aruba Networking 400G VR4 Q-DD MPO12 50m MMF Transceiver (S6H26A) |
Yes |
850 |
MMF MPO12 (APC) |
50/125 |
2000 (OM3) |
30m (OM3) |
|
4700 (OM4 & OM5) |
50m (OM4/OM5) |
|||||
|
Aruba 400G Q‐DD MPO16 SR8 100 m MMF xcvr (R9B41A) |
Yes |
Eight lanes: 850 8x50G PAM4 See "Split to lower‐speed" section |
MMF MPO16 (APC) |
50/125 |
2000 (OM3) |
70 m (229.6 ft) |
|
4700 (OM4 & OM5) |
100 m (328.0 ft) |
|||||
|
HPE Aruba Networking 4x100G DR QSFP‐DD SN 500 m SMF Transceiver (S3N90A) |
Yes |
Per SN channel One lane, 1310, 1x 100G PAM4 Connects to 100G DR (S3N88A) (not compatible to 100G SR4 nor LR4) |
SMF 4xSN (UPC) |
9/125 |
N/a |
500 m (1640.42 ft) |
|
HPE Aruba Networking 400G DR4 QSFP‐DD MPO12 500 m SMF Transceiver (S3N93A) |
Yes |
Four lanes, 1310, 4x 100G PAM4 |
SMF MPO12 (APC) |
9/125 |
N/a |
500 m (1640.42 ft) |
|
Aruba 400G Q‐DD MPO12 eDR4 2 km SMF xcvr (R9B42A) |
Yes |
Four lanes, 1310, 4x 100G PAM4 |
SMF MPO12 (APC) |
9/125 |
N/a |
2 km (1.24 miles) |
|
HPE Aruba Networking 4x100G FR QSFP‐DD SN 2 km SMF Transceiver (S3N91A) |
Yes |
Per SN channel One lane, 1310, 1x 100G PAM4 Connects to 100G FR1 (R9B63A) (not compatible to 100G SR4 nor LR4) |
SMF 4xSN (UPC) |
9/125 |
N/a |
2 km (1.24 miles) |
|
HPE Aruba Networking 400G FR4 QSFP‐DD LC 2 km SMF Transceiver (S3N95A) |
Yes |
Four lanes 1264.5 to 1277.5 1284.5 to 1297.5 1304.5 to 1317.5 1324.5 to 1337.5 Four multiplexed lanes, 100G PAM4 |
SMF LC (UPC) |
9/125 |
N/a |
2 km (1.24 miles) |
|
HPE Aruba Networking 4x100G LR QSFP‐DD SN 10 km SMF Transceiver (S3N92A) |
Yes |
Per SN channel One lane, 1310, 1x 100G PAM4 Connects to 100G LR (S3N89A) (not compatible to 100G LR4) |
SMF 4xSN (UPC) |
9/125 |
N/a |
10 km (6.21 miles) |
|
HPE Aruba Networking 400G PLR4 QSFP‐DD MPO12 10 km SMF Transceiver (S3N94A) |
Yes |
Four lanes: 1310, 4x 100G PAM4 |
SMF MPO12 (APC) |
9/125 |
N/a |
10 km (6.21 miles) |
|
HPE Aruba Networking 400G PLR8 QSFP‐DD 2xMPO12 10 km SMF Transceiver (S4B35A) |
Yes |
Eight lanes: 1310 8x50G PAM4 Connects to 50G LR (S0V65A) or 25G LR (JL486A) when split into separate LC connections |
SMF 2xMPO12 (APC) |
9/125 |
N/a |
10 km (6.21 miles) |
|
HPE Aruba Networking 400G LR4 QSFP‐DD LC 10 km SMF Transceiver (S3N96A) |
Yes |
Four lanes 1264.5 to 1277.5 1284.5 to 1297.5 1304.5 to 1317.5 1324.5 to 1337.5 Four multiplexed lanes, 100G PAM4 |
SMF LC (UPC) |
9/125 |
N/a |
10 km (6.21 miles) |
|
HPE ANW 400G ZR QSFP‐DD 80 km SMF Transceiver (S4B38A) |
Yes |
One lane: 1547.7 1x59.8Gbd DP‐16QAM |
SMF Duplex LC (UPC) |
9/125 |
N/a |
80 km (see note*) |
400G SR8 are not supported for use over OM1/OM2 multimode fiber.
The IEEE standard did not specify any requirements for use over these lower quality multimode fiber.
The MPO16 and MPO12 connectors must be APC (Angled Physical Connector) when connecting to 200G, 400G transceivers to achieve the distance stated above. See the Overview chapter regarding APC vs UPC.
*400G ZR Distance: 80 km is for unamplified point-to-point interface. To achieve 80 km the fiber attenuation needs to be better than 0.25dB/km.
See the "Aruba-Corning 400G Cable Reference Guide" on the HPE Networking Support Portal for more split optical cables specifically for use with 400G products. 400G optics can be split into lower speeds (see 400G Q-DD optical interoperability with slower speed optics for additional details).
|
Product name (SKU) |
Optical parameters (dBm) |
Required power* |
Temperature Ratings |
|
|---|---|---|---|---|
|
Transmit power |
Receive power |
|||
|
Aruba 400G Q‐DD MPO16 SR8 100 m MMF xcvr (R9B41A) |
‐6.5 to +4.0 |
‐8.4 to +4.0 |
10 W |
Commercial (0 to 70°C) |
|
HPE Aruba Networking 4x100G DR QSFP‐DD SN 500 m SMF Transceiver (S3N90A) |
‐2.9 to +4.0 |
‐5.9 to +4.0 |
10 W |
Commercial (0 to 70°C) |
|
HPE Aruba Networking 4x100G FR QSFP‐DD SN 2 km SMF Transceiver (S3N91A) |
‐3.1 to +4.0 |
‐7.1 to +4.0 |
10 W |
Commercial (0 to 70°C) |
|
HPE Aruba Networking 400G FR4 QSFP‐DD LC 2 km SMF Transceiver (S3N95A) |
‐3.2 to +4.4 |
‐7.2 to +4.4 |
8 W |
Commercial (0 to 70°C) |
|
HPE Aruba Networking 4x100G LR QSFP‐DD SN 10 km SMF Transceiver (S3N92A) |
‐1.9 to 4.8 |
‐8.2 to +4.8 |
10 W |
Commercial (0 to 70°C) |
|
HPE Aruba Networking 400G DR4 QSFP‐DD MPO12 500 m SMF Transceiver (S3N93A) |
‐2.9 to +4.0 |
‐5.9 to +4.0 |
10 W |
Commercial (0 to 70°C) |
|
Aruba 400G Q‐DD MPO12 eDR4 2 km SMF xcvr (R9B42A) |
‐3.1 to +4.0 |
‐7.1 to +4.0 |
12 W |
Commercial (0 to 70°C) |
|
HPE Aruba Networking 400G PLR4 QSFP‐DD MPO12 10 km SMF Transceiver (S3N94A) |
‐1.9 to 4.8 |
‐8.2 to +4.8 |
10 W |
Commercial (0 to 70°C) |
|
HPE Aruba Networking 400G PLR8 QSFP‐DD 2xMPO12 10 km SMF Transceiver (S4B35A) |
‐4.5 to +4.2 |
‐10.8 to +4.2 |
13 W |
Commercial (0 to 70°C) |
|
HPE Aruba Networking 400G LR4 QSFP‐DD LC 10 km SMF Transceiver (S3N96A) |
‐2.7 to +5.1 |
‐9.0 to 5.1 |
8 W |
Commercial (0 to 70°C) |
|
HPE ANW 400G ZR QSFP‐DD 80 km SMF Transceiver (S4B38A) |
‐1.0 to +1.0 |
‐22.0 to 0.0 |
20 W |
Commercial (0 to 70°C) |
|
HPE Aruba Networking 400G VR4 Q-DD MPO12 50m MMF Transceiver |
-4.6 to +4.0 |
-6.3 to +4.0 |
9.0W |
15°C to 70°C |
The SN connectors require 2 'clicks' to be fully seated - only inserting to the 1st click will result in an unreliable connection for that channel.
*Wattage may impact operating temperature for select switches.
Aruba 9300-32D switch series limit the use of QDD optics/AOCs of up to 8 modules max at a time, if running at low-line AC Voltage (100VAC-125VAC). Use High-line voltage to install more than 8 products in the 9300 32D. For more details see the CX 9300 Installation and Getting Started Guide.
The 9300 32D and 9300S Switch Series will shutdown a port that may be exceeding the maximum temperature for a transceiver - this is to prevent damage to the transceiver and other components on the switch. The S4B38A 400G ZR optic will take advantage of this protection mechanism. Take measures to cool the switch environment so that the port can be brought back up. If the situation persists, the port will be kept down, awaiting user-interaction.
|
QSFP‐DD capable product name |
SKU |
Minimum software required |
Comments |
|---|---|---|---|
|
Aruba 9300 Switch Series |
‐32D models R8Z96A‐Base
|
R9B41A (SR8), R9B42A(eDR4): 10.10.1000 S3N90A, S3N91A, S3N92A, S3N93A, S3N94A: 10.13.1010 S3N95A, S3N96A: 10.14.1000 S4B35A (PLR8): 10.15.1000 S4B38A (ZR): 10.16.1006 (only on FB model‐R9A29A) |
High‐line AC voltage is required to support more than 8 products (200‐240 VAC). Bench testing the 9300 32D with low line voltage may not be able to properly power up more than 8 products. The S4B35A 400G PLR8 can be split and pairs of fibers can be used to connect to remote 50G LR or 25G LR (all channels need to be the same speed). Use the split 8 25 or split 8 50 commands and connect an SMF MPO12 to 4xLC fiber cables to the cable plant. The MPO12 connectors should be APC for best performance. S4B38A (400G ZR): is only supported in the upper (odd‐numbered) ports on F2B models of 9300‐32D with a 5°C reduction in the maximum operating temperature of the chassis. ZR is not supported on B2F models. |
|
S6H26A (VR4): 10.17.1001 |
VR4 can connect to other side with 200 VR2, 400G OSFP VR4 or 400G QSFP-112 VR4 from server side. |
||
|
Aruba 9300S Switch Series |
‐32C 8D models displayed by CLI show system Base models: S0F95A‐TAA Base, S0F96A‐Base
|
R9B42A, S3N90A, S3N91A, S3N92A, S3N93A: 10.14.0000 S3N95A, S3N96A: 10.15.0005 S3N94A: 10.15.1000 |
QSFP‐DD (Q‐DD) products cannot be used in QSFP ports (1‐16 and 25 ‐ 40) on the 9300S. |
|
S4B38A (ZR): 10.15.1005 S3N94A (PLR4): 10.15.1000 |
S4B38A (400G ZR): is only supported in ports 17, 19, 21 & 23, and only on the FB models with a 10'C reduction in the maximum operating temperature of the chassis. Do not use on BF models or in any other port for thermal reasons. R9B41A(SR8) does not support 8-way split. Can be used as a single link 400G optic using MPO16 cables. R9B41A requires a derate of 5°C in BF models with maximum environment temperature of 35°C. |
||
|
R9B41A (SR8), R4B35A (PLR8): Not supported |
9300S does not support 8‐way splitting, thus, the 400G SR8 (R9B41A) and PLR8 (S4B35A) are not supported. |
||
|
S6H26A (VR4): 10.17.1001 |
VR4 can connect to other side with 200 VR2, 400G OSFP VR4 or 400G QSFP-112 VR4 from server side. |
||
|
Aruba 10040 32C6D models |
S4R58A displayed by CLI (show system)
|
R9B42A, S3N93A, S3N95A, S3N96A, S3N94A, R9B41A (SR8): 10.16.10xx |
|
TAA models:
|
S4B38A (ZR): 10.16.10xx |
S4B38A (ZR) only supported in ports 25, 27, 29 of the F2B switch models (S4R54A or S4R56A) with a 5°C reduction in the maximum operating temperature of the chassis. Not supported in B2F models. |