Switch Alerts

The HPE Aruba Networking Central allows you to configure alerts. For more information on how to configure alerts, see Configuring Alerts.

Table 1: Switch Alerts

Alert

Switch Type

Category

Description

User Configurable Threshold

Default Threshold

Severity Levels Enabled by Default

Health Support

Alert Summary

Auto Close

Auto Close Condition

802.1X Authentication Rejected

AOS-CX

Clients

Generates an alert when the 802.1X authentication server rejects the user credentials.

No

NA

Yes - Info

 

 

 

 

802.1X Authentication Timeout

AOS-CX

Clients

Generates an alert when there is no response from the 802.1X authentication server during the authentication process.

No

NA

Yes - Info

 

 

 

 

802.1X Authentication Timeout - AOS-S Switch

AOS-S

Clients

Generates an alert when there is no response from the 802.1X authentication server during the authentication process.

No

NA

Yes - Info

 

 

 

 

Client did not Receive an IP Address

AOS-CX

Clients

The wired client did not receive an IP address from the DHCP server.

No

NA

Yes - Info

 

 

 

 

Client was Denied Access

AOS-CX

Clients

The AOS-S switch denied access to the client.

No

NA

Yes - Info

 

 

 

 

MAC Authentication Latency

AOS-CX

Clients

AOS-CX clients experienced an unusually long MAC authentication delay.

No

NA

Yes - Info

 

 

 

 

MAC Authentication Rejected

AOS-CX

Clients

Generates an alert when the MAC authentication server rejects the user credentials.

No

NA

Yes - Info

 

 

 

 

MAC Authentication Server Timeout

AOS-CX

Clients

Generates an alert when there is no response from the MAC Authentication Server during the authentication process.

No

NA

Yes - Info

 

 

 

 

Critical Port Down

AOS-CX and AOS-S

Device

Generates an alert when a monitored network port, marked as critical, transitions to a down or inactive state, potentially impacting connectivity. This may occur due to a physical link failure, administrative shutdown of the interface, LACP configuration issues, loop protection detection, security policy violations (such as port security or 802.1X), or Spanning Tree Protocol placing the port in a blocking state.

No

NA

Yes - Major

 

Switch {hostName} interface {intfName} is not forwarding.

 

 

Broadcast Traffic Utilization

AOS-CX and AOS-S

LAN

Generates an alert when the percentage of broadcast traffic on the interface exceeds the threshold.

Yes

Threshold - 5%

Duration - 5 minutes

Yes - Major

Poor and Fair

Switch [hostName] [intfName] had [errorCount]% broadcast traffic in [duration] minutes.

Yes

When the broadcast traffic reaches below the defined threshold.

Incompatible Transceiver

AOS-CX

LAN

Generates an alert when the switch port has incompatible transceiver.

No

NA

Yes - Major

 

Switch {hostname} interface {intfName} transceiver (model: {xcvrModel}, serial number: {xcvrSerialNumber}, product number: {xcvrPartNumber}) is incompatible.

Yes

When the pm_info.connector_status is in SUPPORTED state.

Inconsistent STP Port

AOS-CX

LAN

Generates an alert when the switch has inconsistent STP ports.

No

NA

Yes - Major

Poor and Fair

Switch {hostName} {interfaceName} was blocked by STP due to {inconsistentType}.

Yes

When the inconsistent scenario is resolved.

Interface Alignment Error

AOS-CX and AOS-S

LAN

Generates an alert when the number of switch alignment errors exceeds the threshold value.

Yes

Threshold - 5000 counts

Duration - 10 minutes

Yes - Major

 

Switch {hostName} port {intfName} had {breachedValue} alignment errors for {duration} minutes.

 

 

Interface Collision Error

AOS-CX and AOS-S

LAN

Generates an alert when the number of switch port collision errors exceeds the threshold value.

Yes

Threshold - 5000 counts

Duration - 10 minutes

Yes - Major

Poor and Fair

Switch [hostName] port [intfName] had [errorCount] collision errors for [duration] minutes.

Yes

When the collision errors are lower than the configured threshold.

Interface CRC Error

AOS-CX and AOS-S

LAN

Generates an alert when the number of switch port CRC errors exceeds the threshold value.

Yes

Threshold - 400 counts

Duration - 20 minutes

Yes - Major

Poor and Fair

Switch [hostName] port [intfName] had [errorCount] CRC errors for [duration] minutes.

Yes

When the CRC errors are lower than the configured threshold.

Interface Fragmented Error

AOS-CX and AOS-S

LAN

Generates an alert when the number of fragmented errors exceeds the threshold value.

Yes

Threshold - 5000 counts

Duration - 10 minutes

Yes - Minor

 

Switch [hostName] port [intfName] had [errorCount] fragmented errors for [duration] minutes.

Yes

When the fragmented errors are lower than the configured threshold.

Interface Giants Error

AOS-CX and AOS-S

LAN

Generates an alert when the number of switch port giant errors exceeds the threshold value.

Yes

Threshold - 5000 counts

Duration - 10 minutes

Yes - Major

Poor and Fair

Switch [hostName] port [intfName] had [errorCount] giant errors for [duration] minutes.

Yes

When the giants count is less than the configured threshold.

Interface Receive Utilization

AOS-CX and AOS-S

LAN

Generates an alert when the data reception rate of the port (in terms of utilization as a percentage of total bandwidth available) exceeds the threshold value.

Yes

Threshold - 95%

Duration - 10 minutes

Yes - Major

Poor and Fair

The receive rate on switch [switch_name] interface [intf_name] was [rxRate]% for [duration].

Yes

When the interface's receive rate falls below the configured threshold.

Interface Runts Error

AOS-CX and AOS-S

LAN

Generates an alert when the number of switch port runt errors exceeds the threshold value.

Yes

Threshold - 5000 counts

Duration - 10 minutes

Yes - Major

Poor and Fair

Switch [hostName] port [intfName] had [errorCount] runt errors for [duration] minutes.

Yes

When the runts count is less than the configured threshold.

Interface Self Test Failure

AOS-CX

LAN

Generates an alert when the switch interface self test fails.

No

NA

Yes - Info

 

 

 

 

Interface Transmit Utilization

AOS-CX and AOS-S

LAN

Generates an alert when the data transmission rate of the port (in terms of utilization as a percentage of total bandwidth available) exceeds the threshold value.

Yes

Threshold - 95%

Duration - 10 minutes

Yes - Major

Poor and Fair

The transmit rate on switch [switch_name] interface [intf_name] was [txRate]% for [duration].

Yes

When the interface's transmit rate falls below the configured threshold.

LAG Link Utilization Efficacy

AOS-CX

LAN

Generates an alert when the switch interface is experiencing unequal traffic distribution with a traffic deviation greater than the configured threshold.

Yes

Threshold - 50%

Duration - 5 minutes

Yes - Minor

 

Switch {hostName} interface {lagName} is experiencing unequal traffic distribution with a traffic deviation greater than {threshold}% in {duration} minutes.

 

 

Multicast Traffic Utilization

AOS-CX and AOS-S

LAN

Generates an alert when the multicast traffic percentage exceeds the threshold.

Yes

Threshold - 90%

Duration - 5 minutes

Yes - major

Poor and Fair

Switch [hostName] [intfName] had [errorCount]% multicast traffic in [duration] minutes.

Yes

When the multicast traffic falls below the defined threshold.

PoE Denied

AOS-CX

LAN

Generates an alert when the switch port denies a PoE connection.

No

NA

Yes - Critical

Poor and Fair

Switch [hostName] [intfName] denied PoE connection due to [reason].

Yes

When there is enough power to power up the connected device on the PoE port.

PoE Fault

AOS-CX

LAN

Generates an alert when the switch port detects a fault in the PoE connection.

No

NA

Yes - Critical

Poor and Fair

Switch [hostName] interface [intfName] had PoE faults due to [reason].

Yes

When the switch PoE port has no issues with the attached powered device (PD)

PoE MPS Errors

AOS-CX

LAN

Generates an alert when the switch port had more PoE MPS errors than the threshold value.

Yes

Threshold - 500 counts

Duration - 30 minutes

Yes - Major

Poor and Fair

Switch [hostName] [intfName] had [errorCount] PoE Maintenance Power Signature (MPS) errors in [duration] minutes.

Yes

When the switch's PoE port does not detect any PoE MPS errors.

Port Flaps Detected

AOS-CX and AOS-S

LAN

Generates an alert when the switch port flaps exceeds the threshold value.

Yes

Threshold - 180 flaps

Duration - 60 minutes

Yes - Major

Poor and Fair

Switch [hostName] [intfName] had [errorCount] flaps in [duration] minutes.

Yes

When there are no port flap counts within the given threshold and period.

Queue Distribution Mismatch

AOS-CX

LAN

Generates an alert when the interface transmission rate is greater than or equal to 60 % and all the traffic is going out from a single queue.

Yes

Duration - 5 minutes

Yes - Major

 

Switch {hostName} interface {intfName} is experiencing unequal traffic distribution with {threshold}% traffic on single egress queue {queueName} in {duration} minutes.

No

1. Alert clears when the traffic is distributed to the remaining interface queues of the interface using QOS configurations.

2. Alert clears when the Interface utilization goes below 60% or the Queue Utilization goes below the threshold.

Queue Drops

AOS-CX

LAN

Generates an alert when the queue drop packet count is greater than or equal to 5% of the passed packet counts.

Yes

Duration - 5 minutes

Yes - Major

 

Switch {hostName} interface {intfName} egress queue {queueName} had {threshold}% packet drops in {duration} minutes.

No

Alert clears when the Queue drop rate goes below the threshold.

Transceiver Disabled

AOS-CX

LAN

Generates an alert when the system disables the transceiver due to exceeding its capacity.

No

NA

Yes - Major

 

Switch [hostName] [intfName] transceiver [xcvr_desc] serial number {} part number {} was disabled due to [connector_status_reason]

Yes

When the pm_info.connector_status_reason does not contain the substring disabled by the system.

Transceiver Down

AOS-CX

LAN

Generates an alert when there is a problem with the transceiver or the switch port.

No

NA

Yes - Major

Poor and Fair

Switch [hostName] [intfName] could not access the inserted transceiver.

Yes

When the pm_info.connector is PRESENT.

Transceiver Failure

AOS-CX

LAN

Generates an alert when the transceiver configuration fails because it is not supported by the interface.

No

NA

Yes - Major

Poor and Fair

Transceiver [xcvrName] serial number {} part number {} on switch [hostName] [intfName] is not fully support.

Yes

When the pm_info.connector_status_reason does not contain the substring failed configuration.

Transceiver Receive Power

AOS-CX

LAN

Generates an alert when the transceiver receive power is outside its optimal operational range.

No

Duration - 15 minutes

Yes - Major

Poor and Fair

Transceiver (model: {xcvrModel}, serial number: {xcvrSerialNumber}, product number: {xcvrPartNumber}) on switch {hostName} {intfName} had a receive power of {rxPower} mW which is outside the optimal range ({lowAlarmThreshold} mW - {highAlarmThreshold} mW).

Yes

When the interface admin status is up, pm_info.connector!= missing, and pm_info.<lane_name>..rx_power falls between the low and high thresholds.

Transceiver Requires More Power

AOS-CX

LAN

Generates an alert when the switch port is unable to provide the necessary power for the transceiver.

No

NA

Yes - Major

 

Switch {hostName} {intfName} supplies {portPower} mW and the transceiver requires {xcvrPower} mW.

Model {xcvrModel} with serial number {xcvrSerialNumber} and product number {xcvrPartNumber}.

 

 

Transceiver Speed Incompatible

AOS-CX

LAN

Generates an alert when the switch port does not support the transceiver's speed.

No

NA

Yes - Major

 

Switch {hostName} {intfName} supported speed(s) is {portSpeed} Mbps and the transceiver speed(s) is {xcvrSpeed} Mbps.

Model {xcvrModel} with serial number {xcvrSerialNumber} and product number {xcvrPartNumber}.

 

 

Transceiver Temperature

AOS-CX

LAN

Generates an alert when the transceiver temperature is outside its optimal operational range.

Yes

Duration - 15 minutes

Yes - Major

Poor and Fair

Transceiver (model: {xcvrModel}, serial number: {xcvrSerialNumber}, product number: {xcvrPartNumber}) on switch {hostName} {intfName} had a temperature of {temperature} °C which is outside the optimal range ({lowAlarmThreshold} °C - {highAlarmThreshold} °C).

Yes

When the interface admin status is Up, pm_info.connector!= absentand pm_info.common.Temperature is between the low and high thresholds.

Transceiver Transmit Current Bias

AOS-CX

LAN

Generates an alert when the transceiver transmit current bias is outside its optimal operational range.

Yes

Duration - 15 minutes

Yes - Major

Poor and Fair

Transceiver (model: {xcvrModel}, serial number: {xcvrSerialNumber}, product number: {xcvrPartNumber}) on switch {hostName} {intfName} had a transmit bias of {txBias} mA which is outside the optimal range ({lowAlarmThreshold} mA - {highAlarmThreshold} mA).

Yes

When the interface admin status is Up, pm_info.connector!= absent and pm_info.<lane_name>.tx_bias is between the low and high thresholds.

Transceiver Transmit Fault

AOS-CX

LAN

Generates an alert when the transceiver fault is detected and the laser is disabled.

Yes

Duration - 15 minutes

Yes - Major

Poor and Fair

Transmit Fault Transceiver (model: {xcvrModel}, serial number: {xcvrSerialNumber}, product number: {xcvrPartNumber}) on switch {hostName} {intfName} had a transmit fault.

Yes

When the interface admin status is up, pm_info.connector!= absent, and pm_monitor.<lane_name>.Tx_fault_state is false.

Transceiver Transmit Power

AOS-CX

LAN

Generates an alert when the transceiver transmit power is outside its optimal operational range.

Yes

Duration - 15 minutes

Yes - Major

Poor and Fair

Transceiver (model: {xcvrModel}, serial number: {xcvrSerialNumber}, product number: {xcvrPartNumber}) on switch {hostName} {intfName} had a transmit power of {txPower} mW which is outside the optimal range ({lowAlarmThreshold} mW - {highAlarmThreshold} mW).

Yes

When the interface admin status is up and pm_info.connector != absent and pm_info.<lane_name>.tx_power within the lower and higher threshold

Transceiver Voltage

AOS-CX

LAN

Generates an alert when the transceiver voltage is outside its optimal operational range.

Yes

Duration - 15 minutes

Yes - Major

Poor and Fair

Transceiver (model: {xcvrModel}, serial number: {xcvrSerialNumber}, product number: {xcvrPartNumber}) on switch {hostName} {intfName} had a voltage of {vcc} V which is outside the optimal range ({lowAlarmThreshold} V - {highAlarmThreshold} V).

Yes

When the interface admin status is up, pm_info.connector!= absent, and pm_info.common.voltage is between the low and high thresholds.

BGP Peer Down

AOS-CX

Routing

Generates an alert when the switch BGP peer is down.

No

NA

Yes - Major

 

BGP peer {ipAddress} of switch {hostName} is {newState} for VRF {vrf} with AS {asNumber} on {addFam}.

Yes

When neighbor switch state is back to UP state [Established].

OSPF Peer Down

AOS-CX

Routing

Generates an alert when the switch OSPF peer is down.

No

NA

Yes - Major

Poor and Fair

OSPF peer {ipAddr} of switch {hostName} is {newState} for VRF {vrf}.

Yes

When the OSPF neighborship changes from Down state to any of the UP states.

ARP Security MAC Mismatch

AOS-CX

Security

Generates an alert when the switch disconnects a client because of a MAC address mismatch.

No

NA

Yes - Critical

 

Switch [switch_name], ARP packet received from MAC {sender_mac} on VLAN {vlan_id}, untrusted port {port_name} with ip {ip_addr} is dropped due to MAC mismatch in IP binding table.

Yes

The alert is triggered upon receiving the event and is automatically cleared within 12 hours.

ARP Security Packet Drop

AOS-CX

Security

Generates an alert when a network device, such as a switch or router, detects and drops suspicious or malicious ARP (Address Resolution Protocol) packets to protect the network from ARP-based attacks or misconfigurations.

No

NA

Yes - Critical

 

Switch [switch_name], ARP packet received from MAC {sender_mac} on VLAN {vlan_id}, untrusted port {port_name} with ip {ip_addr} is dropped as there is no corresponding entry in the IP binding table.

Yes

The alert is triggered upon receiving an event and automatically cleared if no additional events occur within 12 hours.

Client Limit Exceeded

AOS-CX

Security

Generates an alert when the switch disconnects a client after the port exceeds the maximum allowed client limit.

No

NA

Yes - Critical

 

Switch [switch_name], client limit exceeded on port {if_name}, caused by an unauthorized client {mac_addr}.

Yes

The alert is triggered upon receiving an event and automatically cleared if no additional events occur within 1 hour.

Duplicate IP Detected

AOS-CX

Security

Generates an alert when the client device on the network is detected using the same IP address as the switch.

No

NA

Yes - Critical

 

Switch [switch_name], duplicate IPv4 address {ip} is detected on interface {port} with a MAC address of {mac}

Or

Switch [switch_name], duplicate IPv6 address {ip} is detected on interface {port} with a MAC address of {mac}

Yes

The alert is automatically cleared based on the status.

RADIUS Server Status

AOS-CX

Security

Generates an alert when the RADIUS server configured on the switch is not reachable.

No

NA

Yes - Critical

 

Switch [switch_name], RADIUS Server with Address:{server_address}, Authport:{server_authport}, VRF_ID:{server_vrfid} is {status}

Yes

The alert is automatically cleared if the issue resolves or remains inactive for a duration of 12 hours.

Rogue DHCP Server

AOS-CX

Security

Generates an alert when the switch detects an unauthorized DHCP server.

No

NA

Yes - Critical

 

Switch [switch_name], server {ip_address} packet received on untrusted port {port} dropped

Switch [switch_name], packet received from unauthorized server {ip_address} on port {port}.

Switch [switch_name], drop offer from {server_ip_address} of {lease_ip_address} address is illegal.

Switch [switch_name], server {ipv6_address} packet received on untrusted port {port} dropped.

Switch [switch_name], packet received from unauthorized server {ipv6_address} on port {port}.

 

The alert is automatically cleared if the issue resolves or remains inactive for a duration of 12 hours.

Rogue IPv6 Router

AOS-CX

Security

Generates an alert when the switch drops a RA/RR packet from a rouge IPv6 router.

No

NA

Yes - Major

 

Switch <switch_name>, ND packet of type = {type} received on port{port} vlan:{vlan-id} with src_mac{mac_addr} is “Dropped”. Count = {count}

Yes

The alert is triggered upon receiving an event and automatically cleared if no additional events occur within 12 hours.

Sticky MAC Move Violation

AOS-CX

Security

Generates an alert when the switch detects a MAC move violation.

No

NA

Yes - Critical

 

Switch [switch_name], port security sticky client move violation triggered on port {port} for client with MAC address {mac_addr}.

Yes

The alert is triggered upon receiving an event and automatically cleared if no additional events occur within 12 hours.

AP Connected 10/100 Mbps

AOS-CX

System

Generates an alert when an AP is operating below expected speeds (for example, stuck at 10 Mbps or 100 Mbps instead of 1000 Mbps) due to misconfiguration, hardware limitations, or cable issues.

No

NA

Yes - Info

 

 

 

 

Button Fault

AOS-CX

System

Generates an alert when the Mode or Reset button functionality is affected.

Note:

This is applicable only for 6200 and 6300 switches.

Yes

Duration - 60 minutes

Yes - Critical

NA

Switch {hostname} {impact_statement}.

Yes

If the event IDs 13801 or 13802 is not generated within 1 hour.

Excessive IP-Exceptions Packets

AOS-CX

System

Generates an alert when the switch experiences excessive IP-exceptions packets.

Yes

Static Guard Rail: 12000

Duration - 5 minutes

Yes - Minor

 

Switch {hostName} CoPP {copp_name} class received {passed_packed} packets which is above the baseline value {baselineValue} for {duration} minutes.

 

 

Excessive Unknown Multicast Packets

AOS-CX

System

Generates an alert when the switch experiences unknown multicast CoPP drops.

Yes

Default Drop Threshold: 40%

Yes - Minor

 

Switch {hostName} CoPP {copp_name} class experienced {drop_percentage}% packet drops over {duration} minutes.

 

 

Excessive Unresolved IP Unicast Packets

AOS-CX

System

Generates an alert when the switch experiences unresolved IP-unicast CoPP drop.

Yes

Default Drop Threshold: 30%

Yes - Minor

 

Switch {hostName} CoPP {copp_name} class experienced {drop_percentage}% packet drops over {duration} minutes.

   

Fan Fault

AOS-CX

System

Generates an alert when the switch fan status is down.

No

NA

Yes - Critical

Poor and Fair

Switch {hostname} fan {} (location-member/slot/fan) changed to state {}.

Yes

When the fan status changes from Fault to OK.

Fan Tray Fault

AOS-CX

System

Generates an alert when the switch fan tray is down.

No

NA

Yes - Critical

 

Switch {hostname} fan tray {} (location-member/slot) serial number {} Part number {} {changed to state {}

Yes

When the fan tray status changes from Down or Failed to Ready.

IP-Exceptions CoPP Drop

AOS-CX

System

Generates an alert when the switch experiences IP-exceptions CoPP drop.

Yes

Default Drop Threshold: 60%

Duration - 5 minutes

Yes - Major

 

Switch {hostName} CoPP {copp_name} class experienced {drop_percentage}% packet drops over {duration} minutes.

 

 

Line Card Fault

AOS-CX

System

Generates an alert when the switch line card is down.

No

NA

Yes - Critical

Poor and Fair

Switch {hostname} line card {} Serial number {} part number {} changed to state {}.

Yes

When the line card status changes from Down or Failed to Ready.

Link MTU Mismatch

AOS-CX

System

The Max Transmission Unit (MTU) is not configured to the same value on both interfaces.

No

NA

Yes - Info

 

[hostName] [portID] with MTU [mtu] is connected to [hostName] [portID] with MTU [mtu].

Yes

When the Maximum Transmission Units [MTUs] are configured same between the devices.

Link Set to Half Duplex

AOS-CX

System

Generates an alert when the devices are connected using half duplex instead of full duplex.

No

NA

Yes - Info

 

[hostName] [port] is connected to [hostName] [port] using half duplex.

Yes

When there are no link-duplex mismatches.

Link Speed Mismatch

AOS-CX

System

The link speed is not configured the same on both link interfaces.

No

NA

Yes - Info

 

[hostName] [portID] is using [speed] and [hostName] [portID] is using [speed].

Yes

When there are no link speed mismatches.

Link PortType Mismatch

AOS-CX

System

Generates an alert when the Link PortType is not configured the same on both link interfaces.

No

NA

Yes - Info

 

[hostname1] [port1] is configured as an [portConfig1] port, and [hostname2] [port2] configured as a [portConfig2] port.

Yes

When the link port types are configured same between the devices.

Loop Detected

AOS-CX

System

Generates an alert when a loop is detected between switches.

Note: This alert is supported on switches running versions 10.13 and above.

Note: This alert monitors abnormal MAC address movements and excessive broadcast traffic to identify switches and interfaces that could be involved in network loops.

No

NA

Yes - Info

 

Single Switch: Switch [hostName] has an L2 loop between [port_1] and [port_2].

Two Switches: There is a L2 loop between [SW1_hostName] {port} and [SW2_hostName] {port}.

More than 2Two Switches: There is an L2 loop involving ([count]) switches.

Yes

When there are no loops in the network.

Management Module Fault

AOS-CX

System

Generates an alert when the switch management module is down.

No

NA

Yes - Critical

Poor and Fair

Switch {hostname} management module {} Serial number {} Part number {} changed to state {}

Yes

When the management module status changes from Down or Failed to Ready.

New Switch Connected

AOS-CX and AOS-S

System

Generates an alert when Aruba Central detects a new switch connection.

No

NA

Yes - Info

 

 

 

 

Partial Input Power Lost

AOS-CX

System

Generates an alert when the switch power supply unit loses input power.

No

NA

Yes - Major

 

Switch {hostname} power supply unit {} (member/slot) serial number {} part number {} lost input power.

Yes

When the power supply status changes from FAULT_INPUT to OK.

PoE Utilization

AOS-CX and AOS-S

System

Generates an alert when the PoE utilization for a port exceeds the critical and major threshold value.

Yes

Threshold - 90%

Duration - 30 minutes

Yes - Major

Poor and Fair

Switch [hostName] [intfName] had [errorCount] flaps in [duration] minutes.

Yes

When the switch PoE utilization falls below the configured threshold.

Power Supply Fault

AOS-CX

System

Generates an alert when the switch power supply is down.

No

NA

Yes - Major

 

Switch [hostName] [intfName] had [errorCount] flaps in [duration] minutes.

Yes

When the power supply status changes to OK from WARNING or FAULT_OUTPUT or FAULT_POE or FAULT_NORECOV OVERVOLTAGE or UNDERVOLTAGE or FAULT_AIRFLOW.

Route Count Above Baseline AOS-CX

System

Generates an alert when the unicast route count exceeds the baseline normal range.

Yes

Static Guard Rail- 1% of maximum limit.

Duration - 5 minutes

 

Yes - Minor   Switch {hostName} unicast routes count has exceeded the baseline value [baselineValue] for {duration} minutes. Yes When the route count falls within the baseline range, the alert is cleared.

Route Count Below Baseline

AOS-CX

System

Generates an alert when the unicast route count goes below the baseline normal range.

Yes

Static Guard Rail - 0.2% of minimum limit.

Duration - 5 minutes

 

Yes - Minor   Switch {hostName} unicast routes count below the baseline value [baselineValue] for {duration} minutes. Yes When the route count falls within the baseline range, the alert is cleared.

Stack Conductor Changed

AOS-CX and AOS-S

System

Generates an alert when the stack conductor is changed.

No

NA

Yes - Minor

 

Switch stack [stackHostname] changed the conductor to [serialNumber] with member ID [memberID].

No

NA

Stack Link Down

AOS-CX

System

Generates an alert when the VSF link goes down in the stacked devices.

No

NA

Yes - Major

 

The VSF link status of stack [hostName] switch [serialNumber] [intfName] changed to [action].

Yes

When the stack link comes up.

Stack Member Added

AOS-CX and AOS-S

System

Generates an alert when a new member is removed from the switch stack.

No

NA

Yes - Info

 

The switch with member ID {memberId} ({serialNo}) and role {memberRole} is added to switch stack {stackHostname}.

No

NA

Stack Member Added / Removed

AOS-CX and AOS-S

System

Generates an alert when a new member is added to a switch stack or an existing member is removed from the switch stack. This alert is applicable only for PVOS devices.

No

NA

Yes - Info

 

 

 

 

Stack Member Down

AOS-CX and AOS-S

System

Generates an alert when the member is disconnected from the switch stack.

No

NA

Yes - Critical

 

The switch with member ID {memberId} ({memberSerial}) and role {memberRoleOld} is disconnected from switch stack {hostName}.

No

NA

Stack Member Removed

AOS-CX and AOS-S

System

Generates an alert when member is added to the switch stack.

No

NA

Yes - Info

 

The switch with member ID {memberId} ({serialNo}) and role {memberRole} is removed from switch stack {stackHostname}.

No

NA

Switch CPU Utilization

AOS-CX and AOS-S

System

Generates an alert when the switch CPU utilization exceeds the threshold value.

Yes

Threshold - 90%

Duration - 5 minutes

Yes - Critical

Poor and Fair

Standalone: The CPU utilization on switch {hostName} was above {threshold}% for {duration} minutes. Stack: The average CPU utilization on switch stack [switch_name] member (ID [Member ID] & SN [serialNumber]) was above {threshold}% for {duration} minutes.

Yes

When the CPU utilization percentage is below the threshold value.

Switch Memory Utilization

AOS-CX and AOS-S

System

Generates an alert when the switch memory utilization exceeds the threshold value. In the Duration field, enter the duration after which the alert must be generated.

Yes

Threshold - 95%

Duration - 5 minutes

Yes - Critical

Poor and Fair

Standalone: The average memory utilization on switch {hostName} was above {threshold}% for {duration} minutes.

Stack: The average memory utilization on switch stack [switch_name] member (ID [Member ID] & SN [serialNumber]) was above {threshold}% for {duration} minutes.

Yes

When the Memory Utilization percentage falls below the threshold value.

Switch Offline

AOS-CX and AOS-S

System

Generates an alert when the switch is experiencing difficulties communicating with Aruba Central.

Yes

Duration - 10 minutes

Yes - Critical

 

 

 

 

Switch Reboot

AOS-CX and AOS-S

System

Generates an alert when a switch has rebooted.

Note:

Switch Reboot alert is not generated for user-initiated actions, such as reboots performed through HPE Aruba Networking Central or during firmware upgrade operations.

No

NA

Yes - Critical

 

Switch {hostName} rebooted due to: {rebootReason}

Yes

The alert is automatically cleared if the issue resolves or remains inactive for a duration of 6 hours.

Temperature Fault

AOS-CX

System

Generates an alert when the switch temperature exceeds the threshold.

Yes

Threshold - 40 Counts

Duration - 5 minutes

Yes - Critical

Poor

The temperature of the switch [hostName] in module {module_type}-{name} is {CRITICAL/OVERTEMP/LOW/CRIT_LOW}.

Yes

When the temperature is lower and its status is Normal.

Transmit Packet Drops

AOS-CX and AOS-S

System

Generates an alert when the transmission drop exceeds the threshold value.

Yes

Threshold - Port utilization must be 5%

Yes - Major

Poor and Fair

Switch [hostName] [intfName] had [errorCount]% transmit packet drops in [duration] minutes.

Yes

When the interface packet drop falls below the threshold percentage.

Unresolved IP Unicast CoPP Drop

AOS-CX

System

Generates an alert when the switch has unresolved IP unicast CoPP drop.

Yessna

Default Drop Threshold: 30%

Duration - 5 minutes

Yes - Major

 

Switch {hostName} CoPP {copp_name} class experienced {drop_percentage}% packet drops over {duration} minutes.

 

 

VSF Standby Missing

AOS-CX

System

Generates an alert when the VSF standby is not configured on the switch.

No

NA

Yes - Major

Fair

Switch {hostName} is missing a VSF Standby member.

 

 

VSX Config Out of Sync

AOS-CX

System

Generates an alert when the configuration of switches in a VSX pair is out of sync.

No

NA

Yes - Minor

Poor and Fair

The VSX configuration on switch [hostName] is not in sync with its peer.

Yes

When the VSX devices are in sync.

VSX Enable/Disable Mismatch

AOS-CX

System

Generates an alert when the ISL (Inter-Switch Link) between the VSX peer switches are not connected.

No

NA

Yes - Critical

 

Operational mismatch detected in VSX Config. May impact connectivity/performance.

Yes

When there is no mismatch in VSX configurations.

VSX ISL Link is Down

AOS-CX

System

Generates an alert when the ISL link is down.

No

NA

Yes - Critical

Poor and Fair

The VSX Inter-Switch Link (ISL) on [hostName] [intfName] is down.

Yes

When ISL link is up.

VSX Keepalive Down

AOS-CX

System

Generates an alert when the keep alive link is down.

No

NA

Yes - Major

Poor and Fair

The VSX keep alive failed on [hostName] link [interfaceName].

Yes

When the keep alive link is up.

VSX Software Version Mismatch

AOS-CX

System

Generates an alert when there is a firmware mismatch between switches in a VSX pair.

No

NA

Yes - Major

Poor and Fair

Switch [hostName] is running firmware [firmwareOne] which is different from its VSX peer. Yes When the VSX devices have the same software version.

Stack Topology is Changed

AOS-CX and AOS-S

System

Generates an alert when one of the VSF links from ring to chain is disabled.

No

NA

Yes - Major

 

Switch stack [stackHostname] changed its topology to [newTopology].

Yes

When the stack topology changed into ring.