Reboot reasons for AOS-CX switches
Table 1: Reboot reasons for AOS-CX
|
Reboot Reasons |
Description |
|---|---|
|
Reboot requested by user |
A user requested a switch reboot through the CLI or web UI. |
|
Reset button pressed |
The switch detected a short-press of the reset button. |
|
Front panel factory reset |
The switch was factory reset via reset button. |
|
Backplane fault |
A backplane fault occurred. |
|
Configuration change |
A configuration change resulted in a reboot |
|
Configuration version migration |
A configuration version migration occurred, which required a reboot |
|
Console error |
Console failed to start. |
|
Fabric fault |
A fabric fault occurred. |
|
All line modules faulted |
A zero line card condition occurred. |
|
Redundancy switchover requested |
A user requested a redundancy switchover. |
|
Redundant Management communication timeout |
The standby management module has taken over from an unresponsive active management module. |
|
Redundant Management election timeout |
A failure to elect a standby management module in the allotted time. |
|
Critical service fault (error) |
A daemon critical to switch operation has stopped functioning. An extra error string may be present to describe the error in detail. |
|
VSF autojoin renumber |
Reset triggered by VSF autojoin. |
|
VSF member renumbered |
A user requested a renumber of a VSF member. |
|
VSF switchover requested |
A user requested a VSF switchover. |
|
VSX software update |
Reset triggered by a VSX software update. |
|
Chassis critical temperature |
Chassis operating temperature exceeded. |
|
Chassis low critical temperature |
Chassis temperature below the minimum operating threshold. |
|
Chassis insufficient fans |
Insufficient fans to cool the chassis. |
|
Chassis unsupported PSUs/fans |
Unsupported or misconfigured PSUs or system fans. |
|
Management module critical temperature |
Management module operating temperature exceeded. |
|
ISSU SMM update |
Standby management module reboot triggered by an In-Service Software Upgrade |
|
ISSU switchover |
Redundancy switchover triggered by an In-Service Software Upgrade |
|
ISSU aborted |
Standby management module reset triggered by failure during an In-Service Software Upgrade. |
|
Rollback timer expired |
Reset triggered by the ISSU rollback timer expiration. |
| JitterEntropy selftest failed | JitterEntropy selftest failed on the system. |
| Crypto selftest failed | Crypto selftest failed on the system. |
| MACsec selftest failed | MACsec selftest failed on one or more interfaces. |
| Hibernation requested | Reboot triggered by a user hibernation request. |
| PSU initiated reboot | Reboot triggered by the PSU due to fault in the input voltage or if PSU input fault is detected. |
| Uncontrolled Reboots | |
| ops-switchd crashed | Reboot triggered due to ops-switchd deamon crash. |
| ovsdb-server crashed | Reboot triggered due to ovsdb server crash. |
Reboot reasons for AOS-S switches
The following are some of the possible reboot reasons for AOS-S switches:
-
Operator reboot from SSH session
-
Reboot of Member ID 1, User reboot
-
Operator reboot from Aruba CENTRAL session
-
Operator reboot from TELNET session
-
Operator reboot from CONSOLE session
-
Operator reboot from Aruba ACTIVATE session
-
Rebooting the device because the module compatibility mode has changed.
-
Rebooting after deleting configuration file.
-
Interface module boot failure
-
Wrong OS reboot
Stack members have different versions compare with the conductor.
-
RFS Error reboot
Flie syncing error across stack members
-
Bad code in flash
-
Non Responsive member
Non responsive member in a stack
-
Removed and rebooted by user
-
Removed by user
-
No remove in progress
-
Lost conductor and standby
-
Lost merge
-
Rebooting for Stacking Admin State change
-
Hardware Access Error reboot
-
Standby not yet sync'd reboot
-
Conductor deassert reboot
-
Member reboot
-
Member shutdown
-
Standby lost during boot
-
Commander lost during boot
-
HeartBeat failure
Heartbeat failure between members in a stack.
-
Backplane communication error
-
Greater than Max Members
-
Mismatch product ID