Appliance Power Consumption

Monitoring > Summary > Appliance Power Consumption

The Appliance Power Consumption tab displays the power consumed by each selected EdgeConnect appliance that supports this feature.

The graph at the top of the tab displays an aggregated view of throughput bytes and power during a specified time range for the selected appliances. Click a predefined time period (1h, 4h, 1d, 7d) to display statistics over the last hour, four hours, day, or seven days. Click Custom and set your own custom time range to display statistics for that time period.

The table at the bottom of the tab displays a list of selected appliances and provides the following information for each appliance:

  • Power Delivered by the Power Adapter (Voltage, Current and Power)
  • Power Delivered by PSU (Voltage, Current and Power)
  • Serial Number of the PSU
  • Firmware Version of the PSU
  • Temperature of the PSU
  • The PSU system connection status
  • The PSU power connection status
Field Description
Appliance Name of the appliance
Model The model number of the appliance (for example, EC-XL, EC10106, EC10104)
Power Supply Type The type of power supply installed in the appliance (Modular - Internal or External power adapter)
Last Week energy (kWh) The total power consumed by the appliance over the last seven days, measured in kilowatt-hours
Last 24h energy (kWh) The total power consumed by the appliance over the last 24 hours, measured in kilowatt-hours
Power (W) The current instantaneous power draw of the appliance, measured in watts
Connection Status (PS 1 / PS 2) Indicates whether the power supply unit is connected and active. Green indicates On; Gray indicates Off. Appliances with an external power adapter display a single connection status indicator.
Input (V) (PS 1 / PS 2) The input voltage for the power supply unit. For modular internal power supplies, this value reflects AC input voltage. For external power adapters, this value reflects DC input voltage.
Current (A) (PS 1 / PS 2) The current draw for the power supply unit, measured in amperes.
Temperature (C) (PS 1 / PS 2) The operating temperature of the power supply unit, measured in degrees Celsius.

The method of obtaining data depends on the type of power supply on the appliance:

  • EC-10104, EC-10106, and EC-10108: Uses an external power adapter. Current and voltage of the power output from the adapter is measured.
  • EC-10150, EC-XL, EC-SP, EC-L, EC-M, and EC-S: Uses a modular power supply. Current and voltage of the power output from the Power supply is measured. In addition to this, serial number, firmware version, and power connectivity status to the power supply is reported.
  • EC-XS and EC-US: Uses an external power adapter. These appliances do not have a provision to measure power consumption.